Skip to main content

Why All Buildings Require Mandatory Tactile Indicator?

 

As business owners, we are always eager to welcome all their customers. We try to make our business reach everyone, including step-free entrances, wide passageways, alarm systems, etc. The mandatory tactileindicator(s) or signs in your building should also be understandable by everyone.

 

Why All Buildings Require Mandatory Tactile Indicator?
mandatory tactile indicator

According to a survey, nearly 20 percent of U.S. citizens have some form of disability. When your business doesn't stand on ADA guidelines and isn't in the reach of anyone, there are always chances of losing customers.

 

Considering the rules and regulations and requirements of the Americans with Disabilities Act (ADA) can encourage your business to gain more customers. As a contractor, you should ISO tactile warning indicators.

 

Tactile Signs: Raised Characters & Braille

 The standards outlined for raised characters in Section 703:

 

·         Uppercase

·         1/32 inch above the background

·         In a sans serif font — decorative or script fonts are not allowed.

·         According to the height of uppercase "I, "must have a height between five-eighths and two inches, according to the height of uppercase "I."

·         The width of the letter "O" will be a minimum of 55% of the height of uppercase "I" and will be a maximum of 110% of "I"  's height.

·         Raised characters can be a half-inch, at least when visual characters are present and deliver similar information.

·         The width of the letter "I" will be, maximum, 15% of its height.

·         Spacing between characters will be one-eighth inch at least.

·         Spacing between separate lines will be at least 135% of the height of the raised characters.

·         The edges of the raised characters should be smooth. They should not be rough or sharp.

 

Braille letters requirements as per Section 703:

 

·         Braille dots have to be the rounded or domed shape.

·         Dots should be 1.5 mm to 1.6 mm in diameter and between 0.6 mm and 0.9 mm in height.

·         The first letter of all sentences, names, and individual letters of the alphabet should be upper case, proper nouns, initials, and acronyms.

 As a contractor or business owner, if you are looking for the best tactile solutions provider, you can consider tactilesoltuion.ca. Dial our toll-free +1-877-761-5354 for ordering.

Comments

Popular posts from this blog

Why are AODA-Compliant Stair Edge Nosing Solutions Important in Building Design?

  The Accessibility for Ontarians with Disabilities Act (AODA) has been in place since 2005, and since then, it has been the responsibility of contractors and building owners to ensure that their premises are compliant with the Act. One of the key ways to ensure compliance is to install Code-Compliant Stair Edge Nosing Solutions in the building design. The purpose of these indicators is to provide a safe and accessible environment for all users, including those with disabilities. By installing Code-Compliant Stair Edge Nosing Solutions, building owners and contractors can ensure that their premises are compliant with the AODA and are meeting the standards set out by the Act . What is Code-Compliant Stair Edge Nosing Solutions? Code-Compliant Stair Nosing Solutions are another essential component of AODA-compliant design. They are considered to provide a safe and accessible environment for users with disabilities. The solutions are typically installed on the edges of stairways a

Access Tile System Is The First Choice For Contractors. Find Out Why.

The importance of installing compliant tactile solutions is increasing with each passing second. There are many accessibility solutions providers out there who emphasize these solutions when undergoing other projects. That is what makes it supercritical to know the nitty-gritty of these solutions. It is the need of the hour for contractors to acquaint themselves with compliant code standards.  These standards generally include color compliance, affordability, and size requirements. Before the contractors delve into installing indicators or nosings or other solutions, they must know whether they comply with all the project standards. Here is a detailed list of points that show why the Access Tile Tactile System is the right choice for the contractors. 1.        They comply with the size requirements. The measurement guidelines are one of the most significant things contractors have to keep in mind while installing the Tactile ground sueface indicators ( TWSI). The ISO Access Tile

Everything you Need to Know about Tactile Walking Surface Indicators

Tactile walking surface indicators play a crucial role in making the facility accessible to pedestrians, especially those with visual impairment. The tactile attention indicators convey information to people about the surroundings through texture and sometimes sound. In most situations, contractors are aware of the importance of installing tactile indicators but are unaware of the code requirements for installing tactile walking surface indicators pathways in Toronto. From the color compliance to design basics and size requirements, contractors have to take various things into account. One thing contractors must note is that the TWSI must provide high tonal contrast with the surrounding surface. Also, most of the indicators installed in the city of Toronto are made of cast iron. Cast iron develops a rusty color in the first year of installation, but the color will fade eventually as cast iron will develop a natural patina. The natural patina provides even greater tonal contrast with